<section data-class="_mbEditor" data-id="1757963" helvetica="" neue",="" "pingfang="" sc",="" "hiragino="" sans="" gb",="" "microsoft="" yahei="" ui",="" yahei",="" arial,="" sans-serif;="" font-size:="" 17px;="" letter-spacing:="" 0.544px;="" text-align:="" justify;="" background-color:="" rgb(255,="" 255,="" 255);="" box-sizing:="" border-box="" !important;="" overflow-wrap:="" break-word="" !important;"="" style="box-sizing: border-box; margin: 0px 0px 24px; display: block; font-family: "microsoft yahei"; font-size: 14px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: start; text-indent: 0px; text-transform: none; widows: 2; word-spacing: 0px; -webkit-text-stroke-width: 0px; white-space: normal; background-color: rgb(255, 255, 255); text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial; padding: 0px; outline: 0px; max-width: 100%; color: rgba(0, 0, 0, 0.9);">
恒温恒湿试验箱能够精密模拟多样化气象场景,严苛检验仪器在不同温湿度条件下的性能与耐候性,进一步巩固其产品的环境适应性和信赖度。
1.试验执行的标准
GB/T 2423.4-2008 电工电子产品环境试验 第2部分:试验方法 试验Db:交变湿热(12h+12h循环)
2.试验流程
1. 试验准备a. 设备校准与检查:校准设备并确认所有传感器和控制系统的精度。
b. 产品准备:检查产品表面是否干净无损,并记录初始状态。
2. 产品放置
a. 放置位置:合理放置产品,确保不阻挡气流和传感器。
b. 密封检查:关闭试验箱门,确保密封良好。
3. 参数设定
a. 温度设定:设定温度循环程序,3小时内升至+40℃或+55℃。
b. 湿度设定:设定湿度范围,升温阶段相对湿度不小于95%,最后15分钟内不小于90%。
4. 试验执行
a. 启动程序:启动预先设定的试验程序,试验箱自动按照设定的温湿度参数运行。
b. 上升温度阶段:
- 在3小时内,箱内温度升至高温值(+40℃或+55℃)。
- 相对湿度不小于95%,最后15分钟不小于90%。
- 此阶段可能出现凝露现象。
c. 高温保持阶段:
- 温度保持在高温限值±2K内,持续12小时。
- 最初和最后15分钟内相对湿度在90%至100%,其余时间保持在93±3%。
d. 降温阶段:
- 温度在3至6小时内降至25℃±3K。
- 降温阶段相对湿度不小于80%。
e. 恒温保持阶段:
- 温度保持在25℃±3K,相对湿度不小于95%,持续12小时,直至24小时循环结束。
5. 数据采集与分析
a. 数据记录:试验结束后,自动记录所有温湿度变化数据及产品状态变化。
b. 数据分析与性能评估:技术团队分析采集数据,出具测试报告,根据产品在不同环境中的表现来优化设计,增强其环境适应性和可靠性。